Why the study?
Optimal atrial lead position in patients requiring dual-chamber pacemaker implantation remains debated, with limited data on clinical outcomes.
Does Bachman bundle pacing compared to right atrial appendage pacing improve clinical and functional cardiac parameters in patients requiring dual-chamber pacemaker implantation?
Cohort (n=301)
No
Does Bachman bundle pacing compared to right atrial appendage pacing improve clinical and functional cardiac parameters in patients requiring dual-chamber pacemaker implantation?
In patients requiring dual-chamber pacemakers, Bachman bundle pacing significantly shortens stimulated p-waves but does not reduce atrial fibrillation incidence and is associated with more mode switch episodes compared to right atrial appendage pacing.
Retrospective single-center data on Bachmann bundle versus appendage pacing leave optimal atrial lead position open; prospective trials needed.
Background: In patients requiring dual-chamber pacemaker (DDD) implantation, optimal atrial lead position remains a matter of debate. While most centers prefer implantation in the right atrial appendage position (Non-BB-P), due to a speculated favorable impact on atrial conduction characteristics, often, a Bachman bundle pacing (BB-P) is recommended. However, data investigating clinical outcomes in these patients are still rare. Methods: To evaluate this issue, in this retrospective single-center study, one-year clinical follow-up, pacemaker interrogations and available echocardiography findings in 301 consecutive patients (BB-P: age 76 ± 10 years, 46.7% female, n = 169; Non-BB-P: 77.6 ± 9 years, 50% female, n = 132, p = n.s.) scheduled for dual-chamber implantation were analyzed. Results: During follow-up, the incidence of atrial fibrillation (AF) remained similar in both groups (BB-P: 38.3%, n = 154 vs. Non-BB-P: 34.2%, n = 117 p = n.s.). However, we detected significantly more mode switch episodes in the BB-P group (BB-P: 51.9%, n = 154 vs. Non-BB-P: 38.8%, n = 116, p = 0.032). Furthermore, left ventricular functional parameters, including left ventricular ejection fraction (BB-P: 57.1 ± 8.4%, n = 60 vs. Non-BB-P: 56.0 ± 9.6, n = 45 p = n.s.) and incidence of diastolic dysfunction (BB-P: 55.2%, n = 67 vs. Non-BB-P: 38.3%, n = 47, p = n.s.), as well as the rate of left (BB-P: 58.8%, n = 68 vs. Non-BB-P: 42.0%, n = 50, p = n.s.) and right atrial dilatation (BB-P: 27.9%, n = 68 vs. Non-BB-P: 28.0%, n = 50 p = n.s.), were not significantly affected by the atrial lead position. However, stimulated p-waves were significantly shorter in BB-P vs. Non-BB-P (BB-P: 132.9 ± 23.7 ms, n = 127 vs. Non-BB-P: 139.6 ± 23.4 ms, n = 93, p = 0.031). Conclusions: In patients requiring dual-chamber implantation, the position of the atrial lead significantly altered atrial conduction, but this did not seem to affect left ventricular function parameters or the occurrence of atrial fibrillation within our follow-up period. Interestingly, we even detected more mode switch episodes in the BB-P group, hinting at an even proarrhythmic potential of BB-P. On the other hand, we found a decreased ventricular stimulation percentage in BB-P vs. Non-BB-P. Further studies should investigate the impact of Bachmann bundle pacing on clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Gharibeh et al. (2025) conducted a cohort in requiring dual-chamber pacemaker (DDD) implantation (n=301). Bachman bundle pacing (BB-P) vs. right atrial appendage position (Non-BB-P) was evaluated on incidence of atrial fibrillation (AF) (p=n.s.).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: