Key result
Endovascular aneurysm repair is associated with a ~2.6 m/s increase in arterial stiffness at one year.
Why the study?
The changes in arterial stiffness, central blood pressure, and factors influencing them after endovascular aneurysm repair in hypertensive patients with aortic aneurysm were not well characterized.
Does endovascular aneurysm repair alter vascular stiffness and central blood pressure at one year in patients with aortic aneurysm and hypertension?
Cohort (n=50)
Does endovascular aneurysm repair alter vascular stiffness and central blood pressure at one year in patients with aortic aneurysm and hypertension?
Mean Difference: 2.6
p-value: p=<0.001
Endovascular aneurysm repair is associated with increased arterial stiffness (cfPWV) and altered pulse wave dynamics at one year, without significant changes in central blood pressure.
May increase arterial stiffness post-EVAR in hypertensive patients; leaves open effects on outcomes and need for targeted monitoring.
Aim. To assess the changes of arterial stiffness, central blood pressure (CBP), and determine the factors potentially influencing them in patients with descending thoracic and abdominal aortic aneurysm, in combination with hypertension, one year after endovascular aneurysm repair ((T)EVAR). Material and methods. Patients ≥18 years of age without clinically significant cardiac arrhythmias were included. Before surgery and a year later, we determined peripheral blood pressure, heart rate (HR), CBP, augmentation index (AIx), pressure at the point of maximum rise of the direct pulse wave (PT1h), time to return of the reflected pressure wave (Tr) and carotid femoral pulse wave velocity (cfPWV). Results. Fifty patients were included (mean age, 68±9 years; 41 men; 16 with descending thoracic aortic aneurysm, 34 with abdominal aortic aneurysm), 23 patients were reexamined. After (T)EVAR, an increase in cfPWV (+2,6 m/s, p<0,001), PT1h (+5 mm Hg, p=0,026), peripheral pulse pressure (+7 mm Hg, p=0,039), heart rate (+5 beats/min, p=0,025). The CBP and AIx values have not changed. The dependence of Tr decrease on the stent-graft length (β=0,42) and the decrease in heart rate (β=-0,52) was found. During the year, 6 cardiovascular events were registered. Conclusion. Graft implantation is accompanied by an increase in cfPWV, regardless of aneurysm location. An increase in PT1h one year after (T)EVAR may reflect a decrease in aortic distensibility and worsening damping function. No changes of CBP and AIx is probably explained by reflected wave characteristics after surgery. Predictors of Tr are — increase in heart rate and implantation of longer stent grafts.
No takes yet. Share an insight, caveat, or question.
Gurevich et al. (2023) conducted a cohort in Descending thoracic and abdominal aortic aneurysm with hypertension (n=50). Endovascular aneurysm repair ((T)EVAR) vs. Baseline (before surgery) was evaluated on Carotid femoral pulse wave velocity (cfPWV) (MD +2.6 m/s, p=<0.001). Endovascular aneurysm repair was associated with an increase in carotid femoral pulse wave velocity (+2.6 m/s, p<0.001) at one year, with no changes in central blood pressure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: