An experimental study was performed on a countercurrent pilot-scale packed scrubber for wet flue gas desulfurization (FGD). The flow rate of the treated flue gas was around 300 Nm 3 /h, so the pilot-plant capacity is one of the largest with respect to other published studies on a pilot-plant wet FGD. The tests were carried out at an SO 2 inlet concentration of 2000 ppm by changing the recycle slurry pH to around 4.8 and the L / G ratio to between 7.5 and 15. Three types of limestone were tested, obtaining desulfurization efficiencies from 59 to 99%. We show the importance of choosing an appropriate limestone in order to get a better performance from the FGD plant. Thus, it is important to know the reactivity (on a laboratory scale) and the sorbent utilization (on a pilot-plant scale) in order to identify if a limestone is reactive enough and to compare it with another type. In addition, by using the transfer-unit concept, a function has been obtained for the desulfurization efficiency, using the L / G ratio and the recycle slurry pH as independent variables. The Ca/S molar ratio is related to these and to the SO 2 removal efficiency. This function, together with a simplified function of the operation variable cost, allows us to determine the pair ( L / G ratio and pH) to achieve the desired SO 2 removal with the minimum operation cost. Finally, the variable operation costs between packed towers and spray scrubbers have been compared, using as a basis the pilot packed tower and the industrial spray column at the Compostilla Power Station's FGD plant (in León, Spain).
No takes yet. Share an insight, caveat, or question.
Ortiz et al. (2006) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: