Key result
Fixation of intertrochanteric femur fractures using enders nailing and cannulated cancellous screws achieved 100% radiological union within 3 months, a mean Harris hip score of 86, and a mean VAS score of 0.9.
Why the study?
Does fixation using enders nail and cannulated cancellous screws improve functional outcomes in patients with intertrochanteric femoral fractures?
Observational (n=30)
No
Does fixation using enders nail and cannulated cancellous screws improve functional outcomes in patients with intertrochanteric femoral fractures?
Fixation of intertrochanteric femur fractures using enders nailing and cannulated cancellous screws achieves good functional outcomes and radiological union with minimal complications.
May support low-cost fixation with good function in observational cohorts; leaves open randomized comparison to standard implants.
Background: The objective was to study functional results of fixation of intertrochanteric fractures of femur using enders nail and cannulated cancellous screws. Methods: This was a prospective observational study. The study was conducted on 30 patients of intertrochanteric femoral fractures who underwent fixation by enders nailing and cannulated cancellous screws in Department of Orthopaedics, GMCH, Aurangabad from January 2018 to January 2021. Patients were assessed functionally using Harris hip score, visual analogue score, and radiological assessment at 3, 6, and 12 months. Results: All patients showed radiological union within 3 months. Functional assessment was done with Visual analogue scale (VAS) in which mean VAS score was 0.9 (range 0-3), mean Harris hip score which was 86 (range 81-90). One patient developed superficial infection at incision site which was treated by giving appropriate antibiotics and one patient complained of prominent nail on medial side of knee which was treated by implant removal after union of fracture. Conclusions: Fixation of intertrochanteric femur fractures using enders nailing and cannulated cancellous screws achieves good stability with minimal complications and improved patients’ outcome in terms of less intraoperative blood loss, less chances of infection, less operative time with minimal patient morbidity and good functional outcome.
No takes yet. Share an insight, caveat, or question.
Aziz et al. (2022) conducted an observational in Intertrochanteric femoral fractures (n=30). Enders nailing and cannulated cancellous screws was evaluated on Functional assessment (Harris hip score and VAS) and radiological union. Fixation of intertrochanteric femur fractures using enders nailing and cannulated cancellous screws achieved 100% radiological union within 3 months, a mean Harris hip score of 86, and a mean VAS score of 0.9.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: