Key result
Robotic and minithoracotomy epicardial LV lead placements show zero 30-day mortality, with shorter times for minithoracotomy.
Why the study?
Minimally invasive robotic-assisted and minithoracotomy incisions are used for epicardial LV lead placement after failed coronary sinus cannulation, but comparative early outcomes and costs are not well characterized.
Does robotic-assisted epicardial LV lead placement improve early outcomes or reduce costs compared to minithoracotomy in patients requiring resynchronization after failed coronary sinus cannulation?
Observational (n=24)
No
Does robotic-assisted epicardial LV lead placement improve early outcomes or reduce costs compared to minithoracotomy in patients requiring resynchronization after failed coronary sinus cannulation?
Absolute Event Rate: 0% vs 0%
Minithoracotomy for epicardial LV lead placement offers equivalent short-term electrophysiologic outcomes to robotic-assisted placement but with significantly shorter operative and mechanical ventilation times.
Equivalent early outcomes support either RA or MT for epicardial LV leads; leaves open randomized comparison of long-term efficacy.
OBJECTIVE: Left ventricular (LV) resynchronization with epicardial lead placement after failed coronary sinus cannulation can be achieved with minimally invasive robotic-assisted (RA) or minithoracotomy (MT) incisions. We evaluated early outcomes and costs after RA and MT epicardial LV lead implantation at our academic center. METHODS: From 2005 to 2010, 24 patients underwent minimally invasive RA or MT epicardial LV lead placement for resynchronization. Patient characteristics, electrophysiologic features, outcomes, and costs were analyzed. RESULTS: Ten patients underwent RA and 14 underwent MT minimally invasive LV lead placement, with no 30-day mortality in either group. Younger patients underwent RA epicardial lead placement (63.8 ± 15.4 vs 75.6 ± 10.0 years; P = 0.03). In addition, although both groups had comparable body surface areas, RA patients had significantly higher body mass index versus MT patients (44.4 ± 17.5 vs 26.9 ± 7.1 kg/m, respectively; P = 0.003). Premorbid risk and cardiovascular profiles were similar across groups. Importantly, pacing threshold, impedance, and postoperative QRS interval were equivalent between groups. Significantly, both operating room and mechanical ventilation durations were higher with RA epicardial placement (P < 0.001). Despite equivalent outcomes, incision-to-closure interval was 48 minutes shorter with MT (P = 0.002). Absolute differences in direct costs between groups were negligible. Despite these differences, resource utilization and lengths of stay were equivalent. CONCLUSIONS: Epicardial LV lead placement is efficacious with either approach. Early outcomes and mortality are equivalent. Greater tactile feedback during operation and equivalent short-term outcomes suggest that MT minimally invasive LV lead placement is the more favorable approach for epicardial resynchronization.
No takes yet. Share an insight, caveat, or question.
Bhamidipati et al. (2012) conducted an observational in Failed coronary sinus cannulation requiring left ventricular resynchronization (n=24). Robotic-assisted (RA) epicardial LV lead placement vs. Minithoracotomy (MT) epicardial LV lead placement was evaluated on 30-day mortality. Robotic-assisted and minithoracotomy epicardial LV lead placement both resulted in 0% 30-day mortality, though minithoracotomy had shorter operating room and mechanical ventilation durations.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: