The aim of this study was to quantify the mechanical properties of the muscles of the buttock, using dynamic compression (5-->30 Hz). Tests were conducted in vitro on porcine muscles, using a lever arm device, which applied a dynamic load onto cylindrical samples. A two-parameter viscoelastic model allowed the calculation of stiffness and damping of the samples with respect to frequency. The average stiffness curve showed a monotonous increase (5 Hz: 8.5 kN/m-->30 Hz: 347 kN/m). Concerning damping, between 5 and 20 Hz, values were typically inferior to 300 Ns/m, which then increased till 30 Hz (556 Ns/m). The lever arm device may be used to evaluate dynamic properties of other biological tissues also.
No takes yet. Share an insight, caveat, or question.
Aimedieu et al. (2003) studied this question.