Key result
Transcatheter mitral valve replacement using a preseptostomy balloon-based trackability assessment resulted in a well-functioning valve and stable hemodynamics at 3-year follow-up.
Why the study?
Mitral annular calcification related mitral stenosis presents a significant therapeutic challenge with limited procedural precision in transcatheter mitral valve replacement.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
A novel preseptostomy balloon-assisted trackability assessment can enhance procedural precision and trajectory optimization during TMVR for severe MAC.
Mitral annular calcification (MAC) related mitral stenosis (MS) presents a significant therapeutic challenge, especially in patients considered high-risk or inoperable. Transcatheter mitral valve replacement (TMVR) has emerged as an alternative, but the procedure remains technically demanding due to anatomical complexities and the risk of complications. We report the case of a 72-year-old man with severe MAC and MS, who successfully underwent TMVR using a 29 mm Edwards Sapien 3 valve. A key innovation in this case was the implementation of a novel balloon-assisted trackability assessment to optimize the trajectory of the delivery system. Prior to septostomy, a noncompliant balloon was positioned and inflated at the mitral level, enabling real-time evaluation of coaxial alignment and confirming the feasibility of advancing the prosthesis along the intended path. Once optimal trajectory was verified, the same balloon was used to perform the septostomy, ensuring accurate and controlled passage of the delivery system, and ultimately facilitating precise implantation. At 3-year follow-up, the patient remained asymptomatic with a well-functioning valve and stable hemodynamics. This case highlights the value of preseptostomy balloon-based trackability assessment as a simple yet highly effective technique to enhance procedural precision in TMVR for MAC.
No takes yet. Share an insight, caveat, or question.
Fabris et al. (2025) conducted a case report in Severe mitral stenosis with extensive mitral annular calcification (n=1). Transcatheter mitral valve replacement (TMVR) with preseptostomy balloon-based trackability assessment was evaluated. Transcatheter mitral valve replacement using a preseptostomy balloon-based trackability assessment resulted in a well-functioning valve and stable hemodynamics at 3-year follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: