Conventional saline-contrast electrical impedance tomography (EIT) perfusion imaging typically requires a brief end-expiratory apnea during saline injection to reduce respiratory interference. However, this maneuver is often difficult or impractical in spontaneously breathing patients. We aimed to evaluate whether a non-apnea saline bolus EIT protocol could produce perfusion maps and ventilation–perfusion-related parameters similar to those obtained with the apnea-based reference protocol. Twenty adult patients who completed both study procedures were included: nasal cannula ( n = 7), high-flow nasal cannula (HFNC, n = 9), and invasive mechanical ventilation ( n = 4). Each patient underwent two saline-contrast EIT perfusion acquisitions: a reference end-expiratory apnea-based acquisition and a non-apnea acquisition during ongoing tidal breathing. The primary outcome was within-patient spatial concordance between perfusion maps, quantified by the pixel-wise Spearman correlation coefficient across lung pixels. Secondary outcomes included Bland–Altman agreement of global ventilation–perfusion-related parameters—specifically global inhomogeneity (GI) indices and percentages of EIT-derived V/Q categories (perfused, ventilated, and V/Q-matched units)—as well as regional correlations across four ventral-to-dorsal regions of interest (ROIs). Pixel-wise analysis demonstrated close within-patient spatial concordance in perfusion mapping ( r = 0.92; IQR, 0.88–0.93). Nineteen of 20 patients (95%) had an individual correlation coefficient > 0.80. Breathing-pattern variability did not differ statistically between protocols, as reflected by the standard deviation of tidal impedance amplitude ( P = 0.12) and respiratory cycle duration ( P = 0.68). Bland–Altman analysis showed small mean biases for GI, and percentages of EIT-derived V/Q categories, although limits of agreement were wider for some derived parameters. Regional analysis demonstrated high correlations for ventilation and perfusion across ROIs, with the strongest V/Q-match correlation in the dorsal dependent region (ROI 4; r = 0.960, P < 0.001). Repeated measures correlation confirmed strong overall within-subject regional associations ( r rm ranging from 0.703 to 0.915, P < 0.001). In this clinically heterogeneous cohort, the non-apnea protocol demonstrated strong within-patient spatial correlation with the reference apnea-based protocol for perfusion mapping; however, weaker agreement and wider limits of agreement for derived classified-pixel percentages support feasibility under the studied conditions without establishing clinical equivalence, diagnostic accuracy, or interchangeability.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: