Aim: The purpose of this study was to evaluate and compare the ultimate tensile strength/fracture resistance of superelastic NiTi wires from two manufacturers 3M Unitek and American orthodontics in as received condition, after 3 months and 6 months of intraoral use. The wires would also be evaluated for surface characteristics under a scanning electron microscope. Materials and methods: Superelastic NiTi wires of 0.016 from 3M Unitek were categorized as group I and from American orthodontics as group II. The subgroup A of groups I and II consisted of 10 unused samples. The subgroups B of groups I and II consisted of wires retrieved after 3 months of clinical use. The subgroup C of groups I and II consisted of wires retrieved after 6 months of intraoral use. Results: The results showed that the ultimate tensile strength of the unused wires of both groups I and II were significantly higher than the used wires of the same group. The unused wires of 3M Unitek were found to have superior ultimate tensile strength than the unused wires from American orthodontics and the difference was statistically significant. Likewise, the ultimate tensile strength of 3M Unitek wires which were unused was significantly higher than used wires at 3 months and 6 months of intraoral use, American orthodontics wires which were unused were also found to have statistically higher ultimate tensile strength that the intraorally placed wires after 3 months and 6 months. The 3M Unitek wires retrieved after 3 months and 6 months of intraoral use showed statistically increased ultimate tensile strength than American orthodontic wires of comparative use. Even the surface topography of 3M Unitek wires which were unused and after 3 and 6 months of exposure to intraoral environment showed less pitting, decrease in indentations and less surface roughness. Conclusion: Super elastic NiTi wires from 3M Unitek were found to be superior to the wires from American orthodontics in as received condition, after 3 months of clinical use and 6 months of clinical use. The surface topography of 3M Unitek wires was found to have less pitting and indentations than American orthodontic wires of comparable use. Wires from both manufactures were found to undergo degradation after clinical use. During the study, it was found that 3M Unitek NiTi superelastic wires had better ultimate tensile strength and surface topography than superelastic NiTi from American orthodontics.
No takes yet. Share an insight, caveat, or question.
Devaprasad et al. (2012) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: