Answers are grounded in this paper and cite their sources.
The line start permanent magnet synchronous motor (LSPMSM) can be used for direct‐on‐line (DOL) starting, so it is easily affected by voltage unbalance. Based on the finite element method (FEM) and analytical method, the influence of voltage unbalance on the steady‐state performance of LSPMSM is studied in this paper. A two‐dimensional finite element model is built, and the armature current, losses and torque ripple as a function of the phase voltage unbalance rate (PVUR) are obtained. The influence mechanism of voltage unbalance on the steady‐state performance of a motor is demonstrated. Finally, a prototype of LSPMSM is manufactured and tested. By comparing the experimental data with the simulation data, the accuracy of the calculation model is verified, and the correctness of the research is proved.
No takes yet. Share an insight, caveat, or question.
Qiu et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: