Key result
Robotic-assisted mitral valve repair yields 0% operative mortality in degenerative disease.
Why the study?
The safety and effectiveness of a recently established robotic-assisted mitral surgery program needed evaluation in a contemporary clinical setting.
Is robotic-assisted mitral valve repair safe and effective in patients with degenerative mitral valve disease?
Cohort (n=59)
No
Is robotic-assisted mitral valve repair safe and effective in patients with degenerative mitral valve disease?
Robotic-assisted mitral valve repair for degenerative disease is safe and effective, facilitating fast postoperative recovery with excellent functional outcomes at 1 year.
Robotic mitral repair appears feasible at new centers; leaves open comparative effectiveness versus conventional techniques.
AIMS: To evaluate the safety/effectiveness of a recently established robotic-assisted mitral surgery program. METHODS: Cohort study with prospective collection of clinical data of 59 consecutive recipients (May 2019-August 2021) of robotic-assisted (fourth-generation platform, DaVinci X) mitral valve repair for degenerative disease, using a totally endoscopic technique. Patients' selection was based on defined anatomical and clinical criteria. We established a dedicated multidisciplinary protocol to facilitate postoperative fast-tracking, and a systematic in-house clinical and echocardiographic follow-up at 3, 6, and 12 postoperative months. RESULTS: All patients (89.8% men, average age 58 ± 12 years) received mitral valve repair; there was no operative mortality, one conversion to sternotomy (1.7%) and one stroke (1.7%). Extubation within the operative theater occurred in 28.8%; average mechanical ventilation time and ICU stay was 2.8 ± 4.1 and 32.5 ± 15.8 h (after exclusion of one outlier, learning-curve period, suffering from perioperative stroke); average postoperative hospital stay was 6.8 ± 3.4 days and 96.6% of patients were discharged home. One patient was transfused (1.7%); there were no other complications. Follow-up revealed stability of the results of mitral repair, with one (1.7%) persistent (>2+/4+) mitral regurgitation, and stability of coaptation height over time. We observed optimal functional results (class I was 98% at 3 months and 96% at 12 months). Quarterly case load consistently increased during the experience. CONCLUSION: This initial experience suggests the reliability and clinical safety of a recently established local robotic-assisted mitral surgery. This strategy can facilitate faster postoperative recovery, and its positioning in the therapeutic armamentarium needs to be defined.
No takes yet. Share an insight, caveat, or question.
Agnino et al. (2022) conducted a cohort in Mitral valve degenerative disease (n=59). Robotic-assisted mitral valve repair was evaluated on Operative mortality. Robotic-assisted mitral valve repair for degenerative disease was safe and effective, with 0% operative mortality, a 1.7% stroke rate, and 96% of patients in functional class I at 12 months.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: