Key result
Final translesional pressure gradient is the sole independent predictor of late angioplasty failure.
Why the study?
The value of the final translesional pressure gradient measured during coronary angioplasty in predicting late clinical outcome had not been determined.
Does the final translesional pressure gradient predict late clinical failure in patients undergoing successful coronary angioplasty for single-vessel disease?
Cohort (n=159)
Does the final translesional pressure gradient predict late clinical failure in patients undergoing successful coronary angioplasty for single-vessel disease?
The final translesional pressure gradient measured during coronary angioplasty is an independent predictor of late clinical failure.
Answers are grounded in this paper and cite their sources.
Final gradient predicts late failure after angioplasty; supports risk stratification but leaves open need for prospective validation.
The final translesional pressure gradient measured during coronary angioplasty correlates with immediate angiographic and clinical results. Whether the pressure gradient is of value in predicting late clinical outcome has not been determined. We therefore obtained complete follow-up information on 159 patients with single-vessel disease who underwent successful coronary angioplasty. Mean follow-up time was 15 +/- 10 months. The occurrence of repeat angioplasty, coronary bypass surgery, recurrent anginal chest pain, or a positive postangioplasty stress test were considered clinical events indicative of late failure. Of the variables age, gender, initial and final translesional pressure gradient, extent of initial and final arterial narrowing, site of dilatation, type of balloon catheter used, number of inflations, and maximal inflation pressure, only the final translesional pressure gradient was predictive of late failure when analyzed by multivariate techniques. Thus, the final translesional pressure gradient is of value in predicting both immediate and late outcome after coronary angioplasty.
No takes yet. Share an insight, caveat, or question.
Hodgson et al. (1986) conducted a cohort in Single-vessel coronary artery disease (n=159). Final translesional pressure gradient was evaluated on Late failure (repeat angioplasty, coronary bypass surgery, recurrent anginal chest pain, or a positive postangioplasty stress test). Final translesional pressure gradient was the only independent predictor of late clinical failure after successful coronary angioplasty in a multivariate analysis.
Synapse has enriched 10 related papers. Consider them for comparative context: