Ethoxyquin is a chemical antioxidant used in feeds, ingredients, fats, and oils. A liquid chromatographic (LC) method for determination of ethoxyquin was developed. The method involves acetonitrile extraction of the sample and isocratic Cis reversed-phase chromatography with ammonium acetate buffer-acetonitrile as mobile phase and fluorescence detection. A collaborative study of the determination of ethoxyquin in various meals and extruded pet foods was conducted by The lams Company Research Laboratory. Eleven laboratories analyzed 16 samples (including 2 blind duplicates) consisting of 7 meat meals and 9 extruded pet foods. Sample means ranged from 0.25 to 289 ppm. Repeatability standard deviations ranged from 0.08 to 3.2 ppm, and repeatability relative standard deviations ranged from 4.5 to 32%. Reproducibility standard deviations ranged from 0.12 to 13 ppm, and reproducibility relative standard deviations ranged from 4.5 to 55%. The LC method for determination of ethoxyquin in feeds has been adopted first action by AOAC INTERNATIONAL.
No takes yet. Share an insight, caveat, or question.
Schreier et al. (1997) studied this question.