Key result
CIED presence is linked to ~58% one-year mortality in Staphylococcus aureus bacteremia.
Why the study?
Extraction of cardiac implantable electronic devices (CIED) is recommended in patients with Staphylococcus aureus bacteraemia (SAB), but studies evaluating long-term prognosis are scarce.
Does extraction of cardiac implantable electronic devices improve outcome in patients with Staphylococcus aureus bacteraemia?
Cohort (n=626)
Does extraction of cardiac implantable electronic devices improve outcome in patients with Staphylococcus aureus bacteraemia?
p-value: p=0.0006
Staphylococcus aureus bacteraemia in patients with CIEDs carries a high one-year mortality (58%), though survival beyond one year is possible in a subgroup despite retaining the device.
SAB with CIED signals high short-term mortality and IE risk; leaves open whether routine extraction improves long-term survival in this observational cohort.
BACKGROUND: bacteraemia (SAB) is recognized as an infection that is difficult to treat and with high risk of device related infection. Extraction/explantation of cardiac implantable electronic devices (CIED) is recommended in SAB patients but studies evaluating long-term prognosis are scarce. MATERIALS AND METHODS: In this retrospective cohort study, 626 consecutive SAB patients were identified in routine diagnostics (November 2014-October 2016). Patient characteristic, infective endocarditis (IE) incidence and mortality were compared for patients with and without CIED. RESULTS: = .0006). One-year mortality was 19/33 (58%) among the SAB CIED patients. Echocardiography was performed in all nine patients with CIED-IE but only in 14/24 (58%) of the 24 SAB CIED patients that were considered not having IE. However, if patients with very early mortality were excluded, echocardiography was performed in 14/17 (82%) of SAB CIED-non-IE patients. CIED extraction/explantation during intravenous antibiotic treatment was only performed in three patients with SAB CIED-IE and in one non-IE patient. One year post treatment initiation, 14 out of 33 SAB CIED patients were alive of whom only one had CIED extraction/explantation performed as part of treatment. CONCLUSION: bacteraemia in CIED patients is associated with poor prognosis but in a subgroup of patients survival beyond one year was seen despite retainment of the electronic device.
No takes yet. Share an insight, caveat, or question.
Snygg‐Martin et al. (2020) conducted a cohort in Staphylococcus aureus bacteraemia (SAB) (n=626). Presence of cardiac implantable electronic devices (CIED) vs. No CIED was evaluated on One-year mortality (p=0.0006). In patients with Staphylococcus aureus bacteraemia, the presence of a cardiac implantable electronic device was associated with a 58% one-year mortality, though some survived without device extraction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: