Answers are grounded in this paper and cite their sources.
The physical characteristics of aqueous foams make them excellent candidates for drilling fluids in geothermal formations.1,2 A major concern in this application is the foam-forming ability of a surfactant system in the harsh geothermal environment. While investigating the stability of various foams in an autoclave, we observed a dramatic increase in drainage times with increasing generation pressure, even though the liquid volume fraction of the foam was held constant. This effect appears to result from a decrease in cell size with increasing autoclave pressure and therefore is an artifact of the foam generation technique in which the pressure path of the foam changes with autoclave pressure. A theoretical model of drainage predicts that drainage times should increase with decreasing cell size, as observed. These results emphasize that proper control of cell size can have a substantial effect on the apparent stability of a foam.
No takes yet. Share an insight, caveat, or question.
Rand et al. (1983) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: