This is the authors' abstract. We don't add key points for this paper.
Purpose To develop a new 17-item Asthenopia Survey Questionnaire(ASQ-17) by Rasch analysis, and to evaluate a score to predict for its clinical application. Methods This cross-sectional study was conducted in the Eye Hospital of Wenzhou Medical University from January 2018 to January 2021. A total of 739 participants were recruited and 680 were involved in the result analysis. Three rounds of Rasch analysis was used to analyze the psychometric characteristics of items and options, and the receiver operating characteristic curve was used to obtain the cut-off value. Results Four phases were involved in the analyses. Phase 1 assessed the original ASQ-19, which has nineteen items and seven options. Phase 1 adjusted the item scoring mode to a four-point Likert response rating scale and combined the 18th and 19th items into a single one item, then ASQ-18 was obtained. Phase 2 analysis resulted in deleting the 11th item, and the ASQ-17 was obtained. Phase 3 and 4 assessed the new ASQ-17. All the evaluation indexes of ASQ-17 were acceptable. Infit and Outfit MnSq values of all items were 0.67 ~ 1.48, the variance explained by the principal component and the unexplained variance explained by the first contrast were 53.90%~59.40% and 1.50 ~ 1.80 in three dimensions. The curve peak of 0,1,2,3 scores in each dimension were separated from each other and in the same order. PSR and PSI values were 2.80 and 0.89, respectively. The functional differences of each item by gender were − 0.23 ~ 0.51logit, by age were − 0.36 ~ 0.62 logit. The mean person location was − 0.80logit. The mean score of dimension A (9.5 ± 4.1 vs 3.5 ± 3.2), B(7.3 ± 3.3 vs 2.5 ± 2.7), C(4.3 ± 2.2 vs 1.4 ± 2.0) and total (21.1 ± 8.1 vs 7.4 ± 7.0) in asthenopia participants were significantly higher than that of non-asthenopia (p values < 0.001). The area under curve(AUC) in two groups was 0.899 (p value < 0.001). Youden’s index was up to the maximum value 0.784 when the cut-off value was 12.5, and the sensitivity and specificity index were 100% and 78.4%, respectively. Conclusion The new ASQ-17 is an effective assessment tool for asthenopia with an optimal cut-off threshold value 12.5, which is suitable for diagnosis and curative effect evaluation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2022) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: