Objective To analyze the acceptance testing items of the CyberKnife® S7™ system and evaluate its technical performance and quality assurance. Methods A comprehensive test was conducted on the CyberKnife® S7™ system, which is equipped with a linear accelerator, X-ray imaging, safety mechanisms, a fixed collimator, an Iris™ collimator, an InCise2™ Multileaf Collimator (MLC), iDMS® data management system, and the Accuray Precision® treatment planning system (TPS). End-to-end (ETE) testing was conducted to assess the overall projection accuracy of the CyberKnife S7 system, with relevant parameters recorded. Addition in quality control during clinical application was analyzed, including the verification results of 72 patients obtained using SRS MapCHECK®. Results The 6 MV X-ray beam exhibited radiation quality and off-axis ratio curves within normal ranges, dose stability and linearity deviations both were below 1.0%. The transmission factors of the fixed and Iris collimators were < 0.2%. Repeatability tests for the 5 mm and 60 mm apertures of the Iris collimator met acceptance criteria. The alignment deviation between the laser and radiation beam centers fell within the standard of < 1 mm. The maximum leakage of the MLC complied with the ≤ 0.5% standard. All three criteria for the leaf positioning accuracy tests were satisfied. The maximum deviation in overall projection accuracy for the fixed, Iris, and MLC collimators was 0.90 mm. Across 83 automated quality assurance (AQA) tests, the average deviation was 0.42 mm. Regarding tracking methods, ETE testing for Xsight lung tracking using fixed and Iris collimators showed the maximum deviations, with averages of 0.59 mm and 0.74 mm, respectively. In contrast, the MLC system showed the highest deviation for Xsight spine tracking, with an average of 0.7 mm. Based on the 2%/2 mm gamma analysis criteria with a threshold of 10%, the gamma pass rate for quality control results of 72 patients was 97.65% ± 2.36%. Conclusion All acceptance testing results of the CyberKnife S7 system met the established standards, confirming its reliability and readiness for clinical deployment. Rigorous quality control during clinical application is importance to ensuring the system's ability to deliver precise and effective treatments. This will safeguard patient outcomes and advance the standardization of patients care in radiotherapy.
No takes yet. Share an insight, caveat, or question.
Gong et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: