Key result
Pleural fluid NT-proBNP identifies heart failure-related effusions with ~95% sensitivity.
Why the study?
The overall diagnostic accuracy of pleural NT-proBNP measurement for identifying pleural effusion due to heart failure had not been systematically reviewed.
Does pleural fluid NT-proBNP accurately diagnose pleural effusion due to heart failure in patients presenting with pleural effusion?
Meta-Analysis
Does pleural fluid NT-proBNP accurately diagnose pleural effusion due to heart failure in patients presenting with pleural effusion?
Odds Ratio: 213.87 (95% CI 122.5–373.4)
NT-proBNP levels in pleural fluid demonstrate high diagnostic accuracy for differentiating cardiac from non-cardiac causes of pleural effusion.
Pleural NT-proBNP demonstrates high diagnostic accuracy for heart failure effusion; leaves open whether it improves routine differentiation beyond Light's criteria.
BACKGROUND: N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleural NT-proBNP for identifying pleural effusion due to heart failure. METHODS: After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. RESULTS: Eight publications met the inclusion criteria. The summary estimates for pleural NT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). CONCLUSIONS: NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.
No takes yet. Share an insight, caveat, or question.
Zhou et al. (2010) conducted a meta-analysis in Pleural effusion due to heart failure. Pleural fluid NT-proBNP vs. Non-cardiac conditions was evaluated on Diagnosis of pleural effusion attributable to heart failure (Diagnostic OR 213.87, 95% CI 122.50 to 373.40). Pleural fluid NT-proBNP showed high diagnostic accuracy for identifying pleural effusion due to heart failure, with a sensitivity of 0.95, specificity of 0.94, and diagnostic OR of 213.87.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: