Answers are grounded in this paper and cite their sources.
Pain management is an area of clinical practice and laboratory medicine that is proving to be extremely challenging. Long-term opioid therapy for management of pain involves prescribing potentially addictive substances, with the additional risk of fatal drug–drug interactions if patients are taking nonprescribed medications or illicit drugs. Providers must determine whether the patient is adherent to the prescribed therapeutic regimen while assessing the risk of off-label prescription or illicit drug use, both for patient safety and for their own risk management. Tools such as the Opioid Risk Tool and the revised Screener and Opioid Assessment for Patients with Pain have been used for behavioral-based risk assessment (1, 2), but these tools rely on self-reporting and subjective interpretation of behaviors, all of which can prove unreliable. Prescription monitoring programs are also used to identify patients who are potentially administered controlled substances from multiple providers (i.e., doctor shopping) (3). Against this backdrop, laboratory testing for drugs provides an opportunity for objective assessment of drug exposure that can supplement the behavioral risk assessment for better treatment of patients. However, there is a lack of consensus or guidance on how to approach laboratory testing for pain management. Toxicology testing in both forensic and clinical laboratories has traditionally used concentration-based cutoffs for determining a positive or negative result; reporting is not simply based on the lowest detection threshold for the testing laboratory [limit of detection (LOD)2]. The LOD can vary between laboratories based on their testing platform, methodology (mass spectrometry vs immunoassay), or regulatory oversight. In workplace drug testing, which is frequently the model applied to toxicology screening in a healthcare environment, concentration cutoff thresholds are established to minimize the possibility of false-positive results. Standard concentration cutoffs for workplace drug testing have been developed by the Substance Abuse and Mental Health Services Administration (SAMHSA) of the US government for certain substances of abuse (4). Although it is important to note that the SAMHSA cutoffs were not established with pain management and long-term opioid therapy in mind, it is possible that they can be modified to reflect long-term dosing of certain opioids while maintaining existing concentration cutoffs for illicit drug use. The SAMHSA and other standard cutoff concentrations for qualitative detection of drugs can be found in Table 1. Concentration cutoffs for toxicology screening (10, 11). 6-MAM, 6-monoacetylmorphine; N/A, not applicable; EDDP, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine; MDMA, 3,4-methylenedioxy-methamphetamine; THC, (1-tetrahydrocannabinol; PCP, phencyclidine. Concentration cutoffs for toxicology screening (10, 11). 6-MAM, 6-monoacetylmorphine; N/A, not applicable; EDDP, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine; MDMA, 3,4-methylenedioxy-methamphetamine; THC, (1-tetrahydrocannabinol; PCP, phencyclidine. If laboratories move away from a standard cutoff concentration, one must consider the technologic limitations of detecting drugs—a laboratory cannot detect substances all the way down to “zero” concentration. A laboratory can determine a limit of quantification (LOQ), which is the lowest concentration to which a numeric value can be assigned, or the LOD, which is the lowest concentration at which an analytical method can distinguish something from nothing. Whether a laboratory chooses to use an LOD or LOQ as the limit for reporting a positive screening result, it is crucial to note that these values are not specific to an instrument model or technology (immunoassay vs mass spectrometry) but rather to the method developed and validated in that specific laboratory. There can be significant variability from 1 laboratory to another with respect to what is considered a positive result. In addition, not only are there differences in the LOD and/or LOQ between laboratories, but there are also differences in the assay precision, so that there may be more false-positive and false-negative findings for an assay with a higher degree of variability, regardless of the cutoff or limit for reporting a positive screening result. It is important to note that concentration cutoffs cannot be avoided for immunoassay testing, as the laboratory is dependent on the manufacturer and commercial availability of calibration material. For laboratory-developed qualitative tests such as those based on LC-MS, there is still a concentration cutoff, but if standard cutoff concentrations are not available (or not used), then the cutoff for a positive result is based on the analytical parameters of the assay (such as LOD or LOQ). It is equally important to note that although any positive screening result is of interest, both for prescribed and illicit substances, for the treatment of patients receiving long-term opioid therapy, the positive result is just a biomarker of exposure rather than adherence. For patients needing long-term medications, a positive result represents only a recent ingestion of the substance, whereas for patients taking medications as needed, urine drug testing will not necessarily provide evidence of compliance/adherence, as a negative result can simply be explained as taking a couple of days off the medicine. The use of standard concentration-based cutoffs is also complicated by the different technologies used for screening and whether the test to which the cutoff is applied is a commercial product cleared by the Food and Drug Administration or a laboratory-developed test—who will be responsible for validating the standard cutoffs? results: Without standardized cutoffs, how can one get consistent interpretation? If 1 laboratory has an LOD cutoff of 2 ng/mL and another uses a concentration cutoff of 2000 ng/mL, do qualitative positive results mean the same from both labs? Although SAMHSA concentration cutoffs are not ideal for treatment of patients on long-term therapy, it is conceivable that a set of cutoff concentrations specific to pain management could be developed. When setting a standard cutoff concentration for this application, it would be important to consider the window of detection in urine based on population pharmacokinetics of that particular drug. For instance, it may be desirable to have a very sensitive assay with a long window of detection for sporadic exposure to an illicit drug, whereas for an opioid prescribed long-term and taken multiple times daily, the window of detection may not be as big a concern, and a longer window of detection (increased sensitivity to exposure) might give a physician a false sense of confidence that a patient is adherent when in fact the patient may be only sporadically exposed to the medication in question. Qualitative toxicology screening in pain management should minimize both false-negative and false-positive results while considering pretest probability—for instance, a prescribed opioid SHOULD be present and would have a high pretest probability of a positive result, whereas heroin SHOULD NOT be present and would have a low pretest probability of a positive result (at least for someone who is not a known drug user). A standard approach to concentration-based cutoffs for toxicology screening in pain management patients would have to consider 2 groups of analytes. For prescribed medications, one would want the cutoff sufficiently high to account for long-term recurrent dosing while avoiding a positive result for sporadic or nonadherent use. For illicit drugs, lower cutoffs are desirable to maximize the windows of detection to assess exposure at any point. Multiple clinical or data-mining studies have been published examining the urine concentration of drugs relative to the prescribed regimen (5–9). Although relating urine concentration of drug or metabolite to the dose of drug taken is not reliable, these studies may be useful to set evidence-based cutoffs that are geared toward pain management or long-term opioid therapy rather than workplace testing. It is important to note that standard concentration-based cutoffs will be complicated by the wide range of urine dilution that can occur between patients, and some type of normalization factor (e.g., creatinine, specific gravity) may need to be considered for standard cutoffs to be successful. A cutoff concentration standard should also include minimum acceptable criteria for assay variability at that particular concentration, as well as an acceptable false-positive or false-negative rate. One approach may be to implement a sliding scale for different drugs related to pretest probability based on prescription patterns and the behavioral risk assessment results. In conclusion, evidence-based standard cutoffs are not only useful but also advisable for pain management patient care. Given the existing quantitative data from large toxicology reference laboratories, it should be possible to derive cutoff concentrations for prescription medications that are consistent with long-term use of the drugs, while maintaining lower cutoffs (with minimum quality criteria such as suitable signal-to-noise ratio or secondary ion fragments for mass spectrometry) for illicit or nonprescribed drugs to keep the window of detection for drugs outside of the prescribed regimen as wide as possible. By stratifying thresholds for detection based on pretest probability and prescribed regimens, urine drug screening will be an even more useful tool in conjunction with clinical risk assessment tools for the treatment of patients needing long-term opioid therapy. limit of detection Substance Abuse and Mental Health Services Administration limit of quantification.
No takes yet. Share an insight, caveat, or question.
William A. Clarke (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: