To produce the necessary secondary ac voltage using a transformer it is sufficient to control the current in the excitation winding so that the secondary voltage matches its desired value. The precision of the resulting secondary voltage, however, is affected by the stability of the voltage control circuit, and there have been practical limits to the achievable precision. Any discussion of the stability of voltage control circuits must begin with a clarification of the relationship between transformer excitation parameters and transformer constants. This paper verifies change in transformer constants to excitation parameters in an effort to develop design guidelines for the voltage control circuit. The B-H loop was found to differ widely for cores using voltage source excitation method, current source excitation method, and flux-controlling type excitation method.