Answers are grounded in this paper and cite their sources.
We evaluate the temperature effect on the X-ray radiation-induced luminescence (RIL) of Cu- or Ce-single-doped and CuCe-codoped silica glass. Previous investigations showed that these optical materials exhibit interesting dosimetry properties, such as very good detection capabilities and linear response over a large range of dose rate. However, several radiation environments, such as space and particle accelerators, also require a careful assessment of the temperature effect. With this aim, we characterize their RIL efficiency and spectral dependence at several irradiation temperatures. We demonstrate that all the investigated materials present a nonnegligible temperature dependence of the RIL in the range -120 °C to 80 °C, whilst preserving linear dose rate dependence at each irradiation temperature. However, the temperature effect on the RIL signal is still compensable via calibration and temperature monitoring.
No takes yet. Share an insight, caveat, or question.
Kerboub et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: