Answers are grounded in this paper and cite their sources.
The uniformity of the flow field and cut tobacco distribution inside the airflow dryer seriously affects the stability of the moisture content of the dried cut tobacco and the sensory quality of the product. The physical field, motion trajectory, and physical state of the cut tobacco inside the HDT3 (High-Speed Drying Tube) airflow drying machine are analyzed using numerical simulation methods. And the flow field structure inside the equipment has been improved by adding flow deflectors at critical locations. The average residence time of the cut tobacco in the HDT3 airflow dryer is about 6.48 s, with a residence time of about 0.378 s in the riser. The temperature difference of cut tobacco with different particle sizes is significant, and the outlet particle temperature gradually decreases as the size increases. The average temperature of cut tobacco at the outlet of the dryer is 371.7K. There is segregation phenomenon at the bend of the cut tobacco, and the average segregation rate at the outlet of the riser is 1.819. The deflector can significantly improve the flow field and particle distribution uniformity inside the riser. After adding the deflector, the velocity deviation of rear sections decreases by 14.47%, 30.29%, 24.06%, and 20.18%, respectively; The cut tobacco segregation degree at the outlet of the riser is reduced to 0.997, and the uniformity of the riser outlet section was improved by about 48.7%.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: