Answers are grounded in this paper and cite their sources.
An ultra-low quiescent current tri-mode DC-DC buck converter is presented in this paper, which is able to handle a 100,000X load range. In pulse width modulation (PWM) and pulse frequency modulation (PFM) mode, adaptive on-time (AOT) V2control is utilized to achieve seamless mode transition and constant switching frequency in PWM mode. A deep green mode (DGM) is proposed for light load, where both the switching loss and the power of control circuitry are minimized. By reducing the comparator current, a delay-based hysteresis window adaptive to load current is generated, reducing the switching frequency and the loss. Meanwhile, the average current of zero current detector (ZCD) and AOT controller are reduced significantly by dynamic biasing. As a result, the efficiency of the converter is improved while maintaining a reasonable output ripple. The proposed converter is implemented in a0.18μm BCD technology. Experimental results show that the converter can provide a 1.6 V output from a 2.7 to 4.7V input for1μA to 100 mA load, while consuming only 490nA quiescent current. The proposed converter achieves a 92.1% peak efficiency and efficiency can be maintained above 80% in a load range of20μA to 60 mA.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: