Key result
A fetal hypoxic index greater than 150 during malaria crisis predicted abnormal fetal heart rate at delivery with high sensitivity (80-100%) and specificity (85-91%).
Why the study?
Can fetal Doppler indices predict abnormal fetal heart rate at delivery in fetuses exposed to maternal malaria infection?
Observational
Can fetal Doppler indices predict abnormal fetal heart rate at delivery in fetuses exposed to maternal malaria infection?
The hypoxic index derived from fetal Doppler measurements can accurately predict abnormal fetal heart rate at delivery in pregnancies complicated by malaria.
Answers are grounded in this paper and cite their sources.
May aid risk stratification in malaria-exposed pregnancies; hypothesis-generating and requires prospective validation before practice change.
OBJECTIVE: Malaria during pregnancy induces deterioration of placental function, resulting in transient fetal hypoxia. Our objective was to evaluate the sensitivity and specificity of fetal Doppler indices for prediction of abnormal fetal heart rate at delivery and to compare the amplitude of the fetal vascular response to malaria in 2 groups of fetuses (1994 and 1996) separated by an interval of 2 years. METHODS: Every day during the crisis, the umbilical and cerebral resistance indices, the cerebral-umbilical resistance ratio, and the hypoxic index (mean percent cerebral-umbilical resistance ratio change x crisis duration) were calculated. RESULTS: In group 2 (1996), the duration of the flow redistribution period was about 7 days (mean cerebral-umbilical resistance ratio change +/- SD, 7%+/-4%; hypoxic index, 49+/-26; premature, 35%; and abnormal fetal heart rate, 17.5%). A hypoxic index greater than 150 predicted abnormal fetal heart rate with high sensitivity and specificity (group 1, 80% and 85%; and group 2, 100% and 91 %). Moreover, in group 2 (1996), the amplitude of the fetal vascular response and the rate of long-duration crisis were significantly lower than in group 1 (1994; P < .01). Nevertheless, the hypoxic index was much more predictive of fetal heart rate at delivery than the amplitude or duration (i.e., crisis duration) of the flow redistribution. CONCLUSIONS: The hypoxic index value during the crisis allowed prediction of abnormal fetal heart rate at delivery. In group 2, the absence of a long-term flow redistribution period and the smaller hemodynamic changes (lower hypoxic index) associated with a lower occurrence of abnormal fetal heart rate could be related to improvement of pregnancy management, acquired protection during the interval between the 2 studies, or both.
No takes yet. Share an insight, caveat, or question.
Arbeille et al. (2002) conducted an observational in Malaria during pregnancy. Hypoxic index > 150 vs. Group 1 (1994) vs Group 2 (1996) was evaluated on Abnormal fetal heart rate at delivery. A fetal hypoxic index greater than 150 during malaria crisis predicted abnormal fetal heart rate at delivery with high sensitivity (80-100%) and specificity (85-91%).
Synapse has enriched 10 related papers. Consider them for comparative context: