The high-frequency isolated power supply with low-voltage large-current output and widely fluctuating input voltage is discussed in this paper. It is described that it is difficult to achieve high efficiency of the power supply with ZVS phase-shift PWM controlled DC-DC power converter mainly due to high conduction power losses in the rectifier stage. The 2-stage DC-DC converter system configuration, which consists of boost ZVS-PWM DC-DC chopper and ZVS full-bridge high-frequency isolated DC-DC converter operating with maximum duty cycle, is presented. An ability to improve efficiency of the power conversion by using 2 stages DC-DC circuit configuration is discussed. 900W-100kHz DC-DC conversion system prototypes were built and tested. An efficiency comparison between full-bridge ZVS phase-shift PWM DC-DC power converter and 2-stage soft-switching DC-DC converter has been made. It is proved that using 2-stage DC-DC converter can improve efficiency under full load.
No takes yet. Share an insight, caveat, or question.
Nakaoka et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: