Key result
Long-term systolic BP variability is linked to ~63% higher mortality per quartile in hemodialysis.
Why the study?
Blood pressure variability is a potential prognostic predictor for all-cause mortality in hemodialysis patients, but the comparative prognostic value of long-term versus intra-dialytic BP variability is unclear.
Does long-term blood pressure variability predict all-cause mortality better than intra-dialytic blood pressure variability in hemodialysis patients?
Cohort (n=611)
Does long-term blood pressure variability predict all-cause mortality better than intra-dialytic blood pressure variability in hemodialysis patients?
Hazard Ratio: 1.628 (95% CI 1.086–2.441)
p-value: p=0.0056
Long-term systolic blood pressure variability, specifically the residual metric, is a strong predictor of all-cause mortality in hemodialysis patients and could serve as a target for BP management.
Supports monitoring long-term SBP variability in hemodialysis; hypothesis-generating, should not yet change practice.
BACKGROUND: Blood pressure variability (BPV) is a potential prognostic predictor for all-cause mortality. OBJECTIVES: We conducted a retrospective cohort study to compare the prognostic value of long-term BPV with intra-dialytic BPV in hemodialysis (HD) patients. MATERIALS AND METHODS: We included 611 HD patients and collected their baseline blood pressure (BP) measurements for 1 year and monitored them for 40 months. Long-term BPV was assessed by pre-dialysis BP SD and pre-dialysis absolute BP residual metric. Intra-dialytic BPV was assessed by intra-dialytic BP average real variability and intra-dialytic absolute BP residual. RESULTS: Long-term systolic BPV showed a weak correlation with mean BP, but a stronger correlation with intra-dialytic BPV. High long-term systolic blood pressure (SBP) SD and long-term SBP residual metrics were associated with high all-cause mortality (p = 0.0084 and 0.0056, respectively), while no such association was found for intra-dialytic BPV or diastolic BPV. According to receiver operating characteristic curve with mortality as dependent variable, long-term SBP residual metric showed the strongest prognostic ability (area under curve [AUC] 0.679, p = 0.0006), which was even stronger in patients with BP ≥140/90 mm Hg (AUC 0.713, p = 0.0004). After completely adjusting for confounders, long-term SBP residual metric remained significantly associated with all-cause mortality (hazard ratio 1.628 per quartile; 95% CI 1.086-2.441). CONCLUSIONS: Our results suggest long-term SBP residual metric to be a better predictor of all-cause mortality in HD patients, which could be used as an additional target for BP management.
No takes yet. Share an insight, caveat, or question.
Liao et al. (2019) conducted a cohort in Hemodialysis (n=611). Long-term systolic blood pressure variability was evaluated on All-cause mortality (HR 1.628, 95% CI 1.086-2.441, p=0.0056). Long-term systolic blood pressure variability was significantly associated with increased all-cause mortality in hemodialysis patients (HR 1.628 per quartile; 95% CI 1.086-2.441).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: