Key result
Low tolerance to simulated hemorrhage is linked to ~22% lower shock index and impaired vagal withdrawal.
Why the study?
Shock index is commonly used to diagnose patients at risk of cardiovascular instability and hemorrhagic shock, but its physiologic basis and accuracy during progressive hemorrhage are unclear.
Does the shock index accurately reflect impending cardiovascular instability in individuals with low tolerance to simulated hemorrhage?
Observational (n=187)
Does the shock index accurately reflect impending cardiovascular instability in individuals with low tolerance to simulated hemorrhage?
Absolute Event Rate: 0.97% vs 1.24%
p-value: p=≤0.002
The shock index has low sensitivity for identifying impending cardiovascular instability in individuals with low tolerance to hemorrhage due to a lower capacity for cardiac vagal withdrawal, potentially leading to undertriage.
Shock index may underestimate instability in low-tolerance patients; leaves open its triage utility pending prospective validation.
BACKGROUND: Shock index (SI), the ratio of heart rate (HR) to systolic arterial pressure (SAP), is a metric often used to diagnose patients at risk of impending cardiovascular instability and hemorrhagic shock. We hypothesized that if SI reflected impending cardiovascular instability and shock in an individual, then: (1) elevations in SI and HR would be greater in individuals with low tolerance (LT) to progressive lower-body negative-pressure (LBNP) compared with individuals with high tolerance (HT), and (2) LT would be associated with greater vagal withdrawal of the baroreflex sensitivity (BRS) compared with HT. METHODS: A total of 187 healthy subjects (HT, 125; LT, 62) underwent exposure to LBNP until a SAP of less than 80 mm Hg (instability) was achieved. HR and SAP were used to calculate SI, and BRS was determined from spontaneous fluctuations in R-R interval and diastolic arterial pressure. Maximal cardiac vagal withdrawal was calculated as the difference between BRS at baseline and BRS at 100% LBNP tolerance. RESULTS: Contrary to our hypothesis, SI at 60%, 80%, and 100% LBNP tolerance in LT (0.59 ± 0.03, 0.73 ± 0.04, and 0.97 ± 0.06, respectively) was lower (p ≤ 0.002) than SI in HT subjects at the same levels (0.66 ± 0.03, 0.84 ± 0.04, and 1.24 ± 0.06, respectively). Maximal cardiac vagal withdrawal was less (p = 0.045) in LT subjects (11.3 ± 2.2 ms/mm Hg) compared with HT subjects (14.9 ± 2.5 ms/mm Hg). The sensitivity of SI in identifying impending instability (SI, 0.9) at 80% and 100% LBNP tolerance was 13% and 63% in LT subjects and 34% and 91% in HT subjects, respectively. CONCLUSION: The low sensitivity of the SI observed in LT individuals is associated with a lower capacity to withdraw cardiac vagal activity and can lead to an undertriage of those patients most likely to develop early hemorrhagic shock.
No takes yet. Share an insight, caveat, or question.
Schafer et al. (2013) conducted an observational in Simulated hemorrhage (n=187). Low tolerance to progressive lower-body negative-pressure vs. High tolerance to progressive lower-body negative-pressure was evaluated on Shock index at 100% LBNP tolerance (p=≤0.002). Low tolerance to simulated hemorrhage was associated with a lower shock index at 100% tolerance compared to high tolerance (0.97 vs 1.24; p≤0.002), indicating a lower capacity for vagal withdrawal.