Key result
High-frequency atrial pacing reliably models AF in dogs with accurate dynamic monitoring via Reveal LINQ.
Why the study?
Insertable cardiac monitor is innovatively used to track the incidence of AF and observe the efficiency and safety of establishing an AF model by high-frequency atrial pacing.
Does the use of an insertable cardiac monitor (Reveal LINQ) accurately track AF load in a dog model of atrial fibrillation induced by high-frequency right atrial pacing?
RCT (n=12)
Randomly divided
Does the use of an insertable cardiac monitor (Reveal LINQ) accurately track AF load in a dog model of atrial fibrillation induced by high-frequency right atrial pacing?
The insertable cardiac monitor Reveal LINQ provides an efficient, sensitive, and accurate method for monitoring AF load in a canine model of pacing-induced atrial fibrillation.
ICM enables reliable AF tracking in paced canine models; leaves open translation to clinical arrhythmia monitoring.
BACKGROUND On the base of traditional modeling with high-frequency atrial pacing, insertable cardiac monitor is innovatively used to track the incidence of atrial fibrillation (AF), to observe the efficiency and safety of establishment in AF model. MATERIAL AND METHODS Twelve adult beagle dogs were randomly divided into a blank control group and an AF model group. The thinnest available bipolar solid electrode lead-3830 was implanted in AF group, connected to AF pacemaker to establish a high-frequency atrial pacing model by AOO pacing mode, and the occurrence of AF was tracked in real time by an insertable cardiac monitor Reveal LINQ. The areas of the left and the right atrium were measured by echocardiography. In addition, the morphology of left atrial tissues was observed using light and electron microscopes. RESULTS The insertable cardiac monitor Reveal LINQ sensitively, conveniently, accurately, efficiently, and dynamically recorded the AF load in AF group. After the successfully establishment of the AF mode, the area of the left atrium and right atrium were significantly enlarged compared with that before modeling by echocardiography. Furthermore, the area of the left atrium and right atrium in the AF group were larger than that in the control group. The morphological observation of the left atrium tissues in both groups prompted the reconstruction of the atrial structure in dogs in the AF group. CONCLUSIONS The application of insertable cardiac monitor Reveal LINQ improves the efficiency of monitoring the AF load, with high sensitivity, convenience, and accuracy.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2020) conducted an RCT in Atrial fibrillation (n=12). High-frequency atrial pacing with insertable cardiac monitor Reveal LINQ vs. Blank control group was evaluated on AF load and atrial area enlargement. High-frequency atrial pacing successfully established an atrial fibrillation model in dogs, and the insertable cardiac monitor Reveal LINQ accurately and dynamically recorded the AF load.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: