Answers are grounded in this paper and cite their sources.
Background: Analysis of aluminium (Al) in urine samples is required in management of a number of diseases including patients with renal failure. This work aimed to present dispersive liquid-liquid microextraction (DLLME) and ultrasound-assisted emulsification microextraction (USAEME) methods for the preconcentration of ultra-trace amount of aluminum in human urine prior to its determination by a graphite furnace atomic absorption spectrometry (GFAAS). Methods: The microextraction methods were based on the complex formation of Al3+ with 8-hydroxyquinoline. The effect of various experimental parameters on the efficiencies of the methods and their optimum values were studied. Results: Under the optimal conditions, the limits of detection for USAEME-GFAAS and DLLME-GFAAS were 0.19 and 0.30 ng mL−1, respectively and corresponding relative standard deviations (RSD, n=5) for the determination of 40 ng mL−1 Al3+ were 5.9% and 4.9%. Conclusion: Both methods could be successfully used to the analysis of ultra trace concentrations of Al in urine samples of dialysis patients.
No takes yet. Share an insight, caveat, or question.
Farajbakhsh et al. (2016) studied this question.