Key result
The HAdV-MCDA-CRISPR assay accurately detected human adenovirus, yielding 78 positive results among 80 HAdV-positive samples and 48 negative results among 48 HAdV-negative samples.
Why the study?
Does the HAdV-MCDA-CRISPR assay accurately detect human adenovirus serotypes 3 and 7 in clinical samples?
Does the HAdV-MCDA-CRISPR assay accurately detect human adenovirus serotypes 3 and 7 in clinical samples?
The HAdV-MCDA-CRISPR assay provides a rapid, sensitive, and highly specific method for detecting human adenovirus serotypes 3 and 7, offering a promising tool for clinical diagnosis.
May support rapid adenovirus detection in clinical samples; leaves open routine adoption pending larger validation studies.
• A novel diagnositc method based on isothermal multiple cross displacement amplification and CRISPR-cas12-based detection was devised for detection of HAdV-3 and HAdV-7. • The new approach exhibited unique advantages of simplicity, speed, and accuracy. • The new nearly equipment-free technique makes it a valuable diagnostic tool for timely diagnosis and intervention of HAdV-3 and HAdV-7 infection. Human adenoviruses (HAdV), particularly serotypes 3 and 7, are significant pathogens that cause respiratory tract infection. Here, we developed a novel HAdV diagnostic assay, termed HAdV-MCDA-CRISPR, by combining multiple cross displacement amplification (MCDA) with CRISPR/Cas12a-based detection. HAdV-MCDA-CRISPR assay uses MCDA to amplify target DNA, followed by detection of predefined sequences using a CRISPR/Cas12a-crRNA complex. Resulting fluorescence from probe cleavage indicates a positive result. A set of 10 MCDA primers and a specific crRNA were designed to ensure high specificity of HAdV-MCDA-CRISPR assay. The entire procedure, including rapid template preparation (∼15 min), MCDA reaction (40 min), and result interpretation (5 min), takes approximately one hour. Targeting the conserved hexon gene, HAdV-MCDA-CRISPR achieves high sensitivity under optimized MCDA reaction conditions (40 min at 66 °C), detecting as little as 1.92 copies/μL of hexon-containing plasmid DNA without cross-reactivity. Validation using 128 clinical samples demonstrated 78/80 positive results for HAdV-positive patients and 48/48 negative results for HAdV-negative patients. Thus, HAdV-MCDA-CRISPR assay offers a promising alternative for rapid and accurate clinical diagnosis of HAdV-3 and HAdV-7 infections.
No takes yet. Share an insight, caveat, or question.
Wan et al. (2025) studied Human adenovirus (HAdV-3 and HAdV-7) infection (n=128). HAdV-MCDA-CRISPR assay was evaluated on Detection of HAdV-3 and HAdV-7. The HAdV-MCDA-CRISPR assay accurately detected human adenovirus, yielding 78 positive results among 80 HAdV-positive samples and 48 negative results among 48 HAdV-negative samples.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: