The calibration of photoacoustic aerosol optical absorption measurements through simultaneous photoacoustic spectroscopy of the oxygen A-band absorption is demonstrated. While aerosol absorption shows no sharp spectral structures for size-distributed aerosols, the molecular oxygen A-band has sharp absorption lines in the near-infrared (i.e., 760–770 nm) spectral region. Line-strength, shape, and broadening of these lines are well known and molecular oxygen is ubiquitous with a constant concentration in the troposphere. Simultaneous photoacoustic spectroscopy of aerosol and molecular oxygen A-band absorption with a tunable, external cavity diode laser yields a convenient calibration for the photoacoustic measurement of aerosol absorption coefficients without the need for pressurized and potentially toxic calibration gases.