A method for determination of the solubilities of methane and carbon dioxide in high-pressure water was developed by direct injection of the sample into a gas chromatograph column. This method used a DVB-EVB-EGDMA packings (80-100 mesh) packed column (3 mm i.d. × 2 m). The column temperature and carrier gas flowrate were optimized for the separation of methane, carbon dioxide and water. The measurement accuracy was greatly improved by installing a check valve in the gas supply system. Solubilities of methane and carbon dioxide were determined from the values obtained from the absolute calibration curve.