Answers are grounded in this paper and cite their sources.
Main Problem: Robotic-assisted techniques are common for living-donor nephrectomy. While robotic stapling offers increased surgeon control, there is limited comparative data versus laparoscopic linear stapler use for ligation of renal vessels. Methods: We retrospectively reviewed 32 consecutive robotic-assisted donor nephrectomies by a single surgeon for perioperative outcomes. Results: Patients in the robotic stapler (RS; N=20) and laparoscopic stapler (LS; N=12) groups were comparable in terms of age and BMI. Estimated blood loss (p = 0.62), warm ischemia time (p=0.50), and console time (p=0.56) were similar between the RS and LS groups. There were no stapler misfires or major intraoperative complications in either group and no cases required conversion to open. Conclusions: Robotic stapler use is safe and effective in robotic-assisted donor nephrectomy. Further research on prevalence of robotic stapler use is needed to quantity the associated complication rate.
No takes yet. Share an insight, caveat, or question.
Giffen et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: