Key result
ResNet-101 neural network categorizes arterial Doppler waveforms with ~84% accuracy vs reference physicians.
Why the study?
Standardized classification of arterial Doppler flow waveforms is recommended for managing lower extremity PAD, but automated categorization methods need evaluation.
Does a pre-trained neural network (ResNet-101) accurately categorize arterial Doppler flow waveforms compared to trained physicians?
Does a pre-trained neural network (ResNet-101) accurately categorize arterial Doppler flow waveforms compared to trained physicians?
Transfer learning on a pre-trained neural network is feasible and achieves high accuracy and agreement for the automatic classification of arterial Doppler flow waveforms.
Answers are grounded in this paper and cite their sources.
May support automated Doppler waveform analysis; leaves open prospective validation before clinical adoption.
BACKGROUND: Arterial Doppler flow waveform analysis is a tool recommended for the management of lower extremity peripheral arterial disease (PAD). To standardize the waveform analysis, classifications have been proposed. Neural networks have shown a great ability to categorize data. The aim of the present study was to use an existing neural network to evaluate the potential for categorization of arterial Doppler flow waveforms according to a commonly used classification. METHODS: The Pareto efficient ResNet-101 (ResNet-101) neural network was chosen to categorize 424 images of arterial Doppler flow waveforms according to the Simplified Saint-Bonnet classification. As a reference, the inter-operator variability between two trained vascular medicine physicians was also assessed. Accuracy was expressed in percentage, and agreement was assessed using Cohen's Kappa coefficient. RESULTS: After retraining, ResNet-101 was able to categorize waveforms with 83.7 ± 4.6% accuracy resulting in a kappa coefficient of 0.79 (0.75-0.83) (CI 95%), compared with a kappa coefficient of 0.83 (0.79-0.87) (CI 95%) between the two physicians. CONCLUSION: This study suggests that the use of transfer learning on a pre-trained neural network is feasible for the automatic classification of images of arterial Doppler flow waveforms.
No takes yet. Share an insight, caveat, or question.
Guilcher et al. (2021) studied Peripheral arterial disease (n=424). ResNet-101 neural network vs. Vascular medicine physicians was evaluated on Accuracy and agreement (Cohen's Kappa) of waveform categorization according to the simplified Saint-Bonnet classification (Kappa 0.79, 95% CI 0.75-0.83). The ResNet-101 neural network categorized arterial Doppler flow waveforms with 83.7% accuracy and a Kappa coefficient of 0.79 compared to a reference physician.
Synapse has enriched 10 related papers. Consider them for comparative context: