Key result
Temporary RVP during coronary arteriography is linked to a ~6-fold higher incidence of ventricular fibrillation.
Why the study?
Few factors have been identified that favor the occurrence of ventricular fibrillation during coronary arteriography despite transient reduction in ventricular fibrillation threshold by contrast dye.
Does the use of temporary right ventricular pacemakers increase the risk of ventricular fibrillation in patients undergoing coronary arteriography?
Observational (n=3,906)
Does the use of temporary right ventricular pacemakers increase the risk of ventricular fibrillation in patients undergoing coronary arteriography?
Absolute Event Rate: 10% vs 1.7%
p-value: p=<.001
The use of temporary right ventricular pacemakers during coronary arteriography is associated with a significantly increased risk of dye-induced ventricular fibrillation.
Rare contrast-induced VF during arteriography supports procedural safety; leaves open systematic identification of predisposing factors.
Each injection of angiographic contrast dye during coronary arteriography represents a "natural experiment" in which the human ventricular fibrillation threshold is transiently reduced. Few factors, however, have been identified which favor the actual occurrence of ventricular fibrillation in this setting. Of 3906 consecutive patients undergoing selective coronary arteriography with sodium meglumine diatrizoate, 66 (1.7 percent) experienced dye-induced ventricular fibrillation, from which all were successfully defibrillated. Analysis of these cases revealed, unexpectedly, that patients in whom temporary right ventricular pacemakers were employed had an incidence of ventricular fibrillation nearly six times that found in the entire group undergoing arteriography (10 percent vs. 1.7 percent, respectively; P less than .001). Those individuals receiving pacemakers were distinguished from other studied patients only by a higher prevalence of conduction abnormalities. Although there is normally a low probability that mechanical stimulation by a pacing catheter can induce ventricular fibrillation, it is postulated that such an occurrence may be more likely after ventricular vulnerability has been increased by contrast dye.
No takes yet. Share an insight, caveat, or question.
Lehmann et al. (1983) conducted an observational in Patients undergoing selective coronary arteriography (n=3,906). Temporary right ventricular pacemaker use vs. Entire group undergoing arteriography was evaluated on Dye-induced ventricular fibrillation (p=<.001). Temporary right ventricular pacemaker use during coronary arteriography was associated with a higher incidence of ventricular fibrillation compared to the overall cohort (10% vs 1.7%; P<0.001).