This paper presents the results of static lateral-load test carried out on a single aluminium model pile embedded in soft clay (consistency index, Ic = 0.42) on a sloping ground. A series of laboratory model tests had been carried out on the instrumented aluminium pile with outer diameter of 25.46 mm on a sloping ground of varying slopes (1V:1H, 1V:1.5H, 1V:2H, 1V:3H and 1V:5H) and with varying embedment length-to-diameter ratio (L/D) of 20, 25 and 30. To quantify the effect of slopes, the tests were also carried out on a horizontal ground surface. From the experimental results, the lateral load-carrying capacity of the pile, load–deflection response of the pile at pile head, effect of slopes and embedment length on pile capacity and bending-moment profile along the pile shaft were studied. The experimental results have been compared with those obtained from finite element analysis PLAXIS 3D and found to be in good agreement.
No takes yet. Share an insight, caveat, or question.
Deendayal et al. (2015) studied this question.