Electrocatalytic oxidation of hydrazine was investigated on a cobalt hydroxide modified glassy carbon (CHM‐GC) electrode in alkaline solution. The process of oxidation involved and its kinetics were established by using cyclic voltammetry, chronoamperometry techniques as well as steady state polarization measurements. In cyclic voltammetry (CV) studies, in the presence of hydrazine the peak current increase of the oxidation of cobalt hydroxide is followed by a decrease in the corresponding cathodic current. This indicates that hydrazine is oxidized on the redox mediator that is immobilized on the electrode surface via an electrocatalytic mechanism. A mechanism based on the electrochemical generation of Co(IV) active sites and their subsequent consumption by the hydrazine in question was also investigated.
No takes yet. Share an insight, caveat, or question.
Hasanzadeh et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: