We describe a pyrophosphate (PPi) probe that is based on a fluorescent dicarboxylate-substituted poly(para-phenyleneethynylene) (PPE) and 10 nm cobalt-iron spinel nanoparticles (NPs) in aqueous media. The spinel NPs efficiently quench the fluorescence of the PPE at a concentration of 20-30 pmol. Addition of phosphate anions to the PPE-NP construct displaces the quenched PPE to give rise to a fluorescent response; we found that PPi and phosphate (Pi) have significantly different binding affinities for the self-assembled materials. We can discern >40 nM PPi in the presence of 0.1 mM Pi at pH 7, which suggests that these assemblies may be useful in bio-analytical applications. This displacement assay was used to effectively determine the ability of pyrophosphatase to hydrolyze PPi to Pi.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2008) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: