Experimental study demonstrates high-sensitivity methylamine detection using tin oxide-decorated polymer nanofibers on a microbalance, indicating a viable platform for real-time hazard monitoring.
Excessive exposure to methylamine gas can have negative effects on human health. Therefore, a new, low-cost, portable, and real-time method for detecting methylamine gas is urgently needed. This study developed a quartz crystal microbalance (QCM)-based methylamine gas sensor with a polyethylene oxide (PEO) and SnO 2 active layer. We used a combination of electrospinning and dropcasting to coat the QCM surface. Adding SnO 2 significantly improved the sensor's performance. The fabricated sensor has a sensitivity of 0.323 Hz·ppm −1 , which is much higher than that of the sensor without SnO 2 . The fabricated sensor also showed a low detection limit, good repeatability and reversibility, and rapid response and recovery times. In addition, the sensor showed reasonable stability. Moreover, the sensor showed exceptional selectivity towards other gas analytes, including alcohol, benzene, toluene, xylene, and acetone. Lewis acid–base interactions are believed to be the main sensing mechanism between SnO 2 and the gas analyte molecules. In addition, density functional theory (DFT) analysis is used to assess agreement between experiments and simulations and to support the proposed sensing mechanisms. Overall, the performance test demonstrates that the fabricated sensor can be an excellent alternative for detecting methylamine gas.