Introduction: We report a novel technique for the vaginal placement of a single-incision laparoscopic device to aid in the removal of pelvic and para-aortic lymph nodes in patients undergoing gynecologic cancer surgery.Technique Description: Informed consent for laparoendoscopic single-site total hysterectomy and bilateral salpingooophorectomy with pelvic and para-aortic lymph node dissection was obtained.A single-incision laparoscopic device was placed through a 2.5-cm umbilical incision, and a total laparoscopic hysterectomy with removal of the ovaries and tubes was performed.Preoperative pathologic analysis showed a grade 2 endometrioid adenocarcinoma of the endometrium, and as a result, bilateral pelvic and para-aortic lymph node dissection was completed.To aid in the lymphadenectomy, an additional transvaginal single-incision laparoscopic device was placed.The procedure was completed in 221 minutes, with 125 minutes spent on the pelvic and para-aortic lymph node dissection.There were no intraoperative or postoperative complications.The amount of blood loss was 50 mL.There were 10 pelvic lymph nodes and 5 para-aortic lymph nodes removed, with no carcinoma detected.The patient tolerated the procedure well and was discharged home the next day.Discussion: Placement of a second transvaginal port is a feasible technique that provides great flexibility and assistance for lymph node removal in gynecologic cancer surgery.