Key result
Thoracoscopic all-box clamping achieves ~93% sinus rhythm at discharge with zero complications.
Why the study?
Current thoracoscopic epicardial surgical ablation strategies for non-paroxysmal atrial fibrillation are complex and often avoided, necessitating simpler effective approaches.
Is totally thoracoscopic all-box clamping safe and effective for the treatment of atrial fibrillation?
Cohort (n=42)
No
Is totally thoracoscopic all-box clamping safe and effective for the treatment of atrial fibrillation?
Totally thoracoscopic all-box clamping is a safe and feasible modified surgical ablation technique for atrial fibrillation, achieving high rates of short-term sinus rhythm.
Answers are grounded in this paper and cite their sources.
All-box clamping was safe and feasible with high discharge sinus rhythm rates; leaves open long-term durability versus standard thoracoscopic ablation.
Background: Epicardial surgical ablation is an effective strategy to treat non-paroxysmal forms of atrial fibrillation. Current thoracoscopic epicardial surgical strategies are complex, and are therefore often avoided. With slight modifications to the thoracoscopic maze procedure, totally thoracoscopic all-box clamping may facilitate the performance of epicardial thoracoscopic ablation, while maintaining good results. Methods: Between December 2023 and December 2024, 42 patients underwent thoracoscopic all-box clamping at a single center. All-box clamping uses commercially available bipolar radiofrequency clamps for isolation of the ipsilateral pulmonary veins and posterior left atrial wall through right and then left-sided thoracoscopic access. The left atrial appendage is occluded using a clip device, and the ligament of Marshall is transected. Assessment of a bidirectional block confirmed electrical isolation. Data from the CASE-AF registry were analyzed retrospectively. Short-term results pertaining to efficacy and safety are provided. Results: All-box clamping was successfully offered to all patients by three surgeons. There were no reported major or minor complications. The median hospital stay was 6 days (interquartile range 5-6). At discharge, a sinus rhythm was observed in 92.9%, and in 76.1% of patients off any class I/III antiarrhythmic drugs. Conclusion: Surgical ablation with a modified thoracoscopic technique is safe and feasible for the treatment of atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Doll et al. (2025) conducted a cohort in Atrial Fibrillation (n=42). Thoracoscopic all-box clamping was evaluated on Sinus rhythm at discharge. Thoracoscopic all-box clamping for atrial fibrillation resulted in no major or minor complications and achieved sinus rhythm in 92.9% of patients at discharge.
Synapse has enriched 10 related papers. Consider them for comparative context: