This is the authors' abstract. We don't add key points for this paper.
Indoor dust is an integrative matrix for assessing human exposure to chemicals released from building materials, consumer products, and human activities. Although residential dust has been extensively investigated, occupational and public indoor environments remain comparatively understudied. Hospitality venues represent shared microenvironments of occupational and public-health relevance, characterized by high occupancy, continuous customer turnover, and intense human activity. To comprehensively characterize this complex matrix, broaden chemical coverage, and minimize analyte losses, a miniaturized, multiclass, single-step supramolecular solvent (SUPRAS)-based extraction method was optimized, validated, and coupled with LC–QTOF-MS analysis. The method enabled the quantitative determination of bisphenols, organophosphate flame retardants, pesticides, per- and polyfluoroalkyl substances, and stimulants, together with database-assisted target and suspect screening. The method was applied to 14 dust samples collected from bars and restaurants in southern Spain. Concentrations varied over several orders of magnitude, with caffeine as the dominant compound, reaching 10 3 –10 6 ng g -1 . Nicotine, cotinine, bisphenol S, and triphenyl phosphate were generally detected at concentrations spanning 10 2 –10 5 ng g -1 . Screening-level workplace dust intakes (WDIs) through incidental ingestion were highest for caffeine, while BPA WDIs were numerically exceeded the current tolerable daily intake in all samples where BPA was quantified; however, these workplace-specific estimates should not be interpreted as total daily intake. Screening further revealed a broad range of pharmaceuticals, drug-related compounds, surfactants, plasticizers and other polymer-related chemicals, personal-care product ingredients, and naturally occurring compounds. Based on the literature consulted, 16 compounds provided potentially novel occurrence or detection-frequency data for indoor dust. Overall, these findings identify bars and restaurants as chemically complex yet understudied indoor microenvironments and demonstrate the suitability of the SUPRAS–LC–QTOF-MS workflow for the broad-scope characterization of complex organic chemical mixtures in indoor dust.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Pérez et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: