Key result
Parkinsonian tremor artifacts can mimic atrial flutter on ECG, risking unnecessary treatment.
Why the study?
Tremor-induced electrocardiographic artifacts can mimic atrial flutter and lead to misdiagnosis and inappropriate management.
Case Report (n=1)
Tremor-induced ECG artifacts in Parkinson's disease can mimic atrial flutter, highlighting the need for careful ECG interpretation to avoid unnecessary interventions.
Answers are grounded in this paper and cite their sources.
Raises awareness of ECG pitfalls in Parkinson's; leaves open whether standardized artifact protocols reduce misdiagnosis rates.
Atrial flutter (AF) is the second most common supraventricular tachyarrhythmia following atrial fibrillation. We present an interesting case of a diagnostic challenge manifested as an electrocardiogram (ECG) recording mimicking AF in a patient with Parkinson's disease (PD). A 72-year-old African-American female with history of PD presented to our Emergency Department with a one day history of chest pain. Her vital signs were within normal limits. Physical exam was remarkable for bilateral resting hand tremors at a frequency of 6-8 hertz and mild cogwheel rigidity in both upper extremities. Initial ECG was interpreted as AF prompting admission. After careful review of her ECG by a cardiologist, several features such as, sharply contoured upright p waves in all leads, different flutter wave morphologies in the same leads, more prominence of "pseudo-flutter" waves in the limb leads compared to the precordial leads, and return to isoelectric baseline after sharp peaked p waves, questioned the diagnosis of AF. A repeat 12 lead ECG clearly demonstrated normal sinus rhythm, and the patient remained completely asymptomatic throughout the stay. A 48-hour Holter monitoring in the clinic later confirmed consistent sinus rhythm with no evidence of any arrhythmias Tremor induced artifacts can be mistaken for arrhythmias. Correct and accurate diagnosis is critically important, in order to avoid wrong treatment and unnecessary interventions. Our case illustrates the importance of recognizing artifact related ECG changes to prevent unnecessary treatment and hospital admissions.
No takes yet. Share an insight, caveat, or question.
Sareen et al. (2018) conducted a case report in Parkinson's disease with ECG artifact mimicking atrial flutter (n=1). Tremor-induced ECG artifact was evaluated on Accurate diagnosis of underlying rhythm. Tremor-induced ECG artifacts in a patient with Parkinson's disease can mimic atrial flutter, highlighting the importance of careful ECG review to prevent unnecessary treatment.