The reinforced concrete structure in marine environment suffered from serious chloride-induced corrosion, which resulted in the reduction in the design life of structure. With the requirement of ultralong service life of Hong Kong-Zhuhai-Macao Bridge (120 years), stainless (SS) and epoxy coated rebar (ECR) instead of steel were used in infrastructure typically corresponding to the splash zone. However, the long-term corrosion performance of different steel in high pressure concrete under chloride attack was rare reported. Herein, both SS, EC and steel after exposed to marine environment for 3 and 7 years were comparative studied. The electro-chemical tests indicated that EC exhibited the best anti-corrosion performance with the positive open circuit potentials (OCP, -0.02 V vs CSE), lowest corrosion current density ( i corr , 4.41×10 -5 μAcm -2 ) and highest polarization resistance (100834 Ω). With the increasing exposed time, the OCP of steel was slightly decreased, it is probability due to the penetration of sea water to concrete. Inversely, the OCP of SS and ECR was increased. An abnormal phenomenon of SS in electrochemical impedance spectrum (EIS) was observed, the impedance of SS was much lower than that of ECR, even lower to steel. The passivation behaviors of SS and steel in concrete were further compared.