Structured packed columns are widely used in the chemical industry for distillation and absorption. However, the understanding of the transfer mechanism behind the counter‐current gas‐liquid flow in structured packed columns is still limited. In this work, a three‐dimensional CFD model that considers the local absorption and the local momentum transfer mechanism is developed for a film flow on a small plate with a counter‐current gas flow. The model, based on the Volume of Fluid (VOF) method, is built up on the basis of a pressure drop model and the penetration theory to quantitatively investigate the instantaneous hydrodynamics and mass transfer characteristics of the liquid phase. Simulations and experiments are carried out for a system consisting of propane and toluene. A comparison of the simulation results with the experimental data for the outlet concentrations shows good agreement.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: