Key result
Percutaneous transluminal radiofrequency closure achieves 100% complete occlusion of small coronary branches in preclinical testing.
Why the study?
The safety and effectiveness of a novel method for selective transcoronary closure of small coronary arteries by intraluminal radiofrequency energy were investigated.
Does percutaneous transluminal radiofrequency closure safely and effectively close small coronary arteries in a canine model?
Does percutaneous transluminal radiofrequency closure safely and effectively close small coronary arteries in a canine model?
Percutaneous transluminal radiofrequency closure is a feasible and safe method for occluding small coronary arteries in an animal model.
RF closure of small coronary branches is feasible in canines; leaves open human safety, efficacy, and clinical translation.
The aim of this study was to investigate the safety and effectiveness of a novel method for the selective transcoronary closure of small coronary arteries by the intraluminal application of radiofrequency (RF) energy. Twenty-six small (diameter of 1-2 mm) coronary artery branches were selected in 13 dogs. An RF electrode wire (CRW-Zcy) was placed into the target vessel and a coronary balloon was used to transiently block the blood flow and limit damage to the proximal vessel. A therapeutic dosage of 20-30 W of RT energy every 10-30 sec (selected according the diameter of the target artery) was discharged via the CRW-Zcy inside a microcatheter two or three times in order to achieve arterial closure. A high dosage of 60 W every 120 sec of RF energy was used to conduct the safety study. All 26 branches were successfully closed resulting in the complete blockage of the antegrade and retrograde flows. The area of injury was limited to the target artery and the supplied myocardium. High-dose RF did not cause injury to the adjacent vessels and myocardium. The animals tolerated the procedure well without any untoward systemic effects. A follow-up angiography at two weeks revealed no evidence of recanalization or retrograde filling of the target artery. Percutaneous transluminal radiofrequency closure is a safe and effective interventional approach for closing the small coronary arteries, and is potentially valuable for further investigation.
No takes yet. Share an insight, caveat, or question.
Chenyun et al. (2013) studied Healthy dogs (investigating closure of small coronary arteries) (n=13). Percutaneous transluminal radiofrequency closure (PTRFC) was evaluated on Successful closure of target vessels. Percutaneous transluminal radiofrequency closure successfully achieved complete occlusion in all 26 targeted small coronary artery branches in dogs without causing injury to adjacent vessels.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: