Key result
The type of explanted valve (mechanical vs bioprosthetic) did not significantly affect in-hospital mortality during reoperative aortic valve replacement (7.1% vs 5.9%; OR 0.62; 95% CI 0.37-1.05; P=0.1).
Why the study?
The impact of explanted valve type on reoperative outcomes in aortic valve surgery was not well defined in a nationwide UK cohort over a long-term period.
Does the type of explanted valve (mechanical vs bioprosthetic) impact in-hospital mortality in patients undergoing first-time isolated reoperative aortic valve replacement?
Cohort (n=2,371)
Yes
Does the type of explanted valve (mechanical vs bioprosthetic) impact in-hospital mortality in patients undergoing first-time isolated reoperative aortic valve replacement?
The type of previously implanted aortic valve (mechanical vs bioprosthetic) does not significantly impact in-hospital mortality during isolated reoperative aortic valve replacement.
OBJECTIVES: This nationwide retrospective cohort study assessed the impact of the explanted valve type on reoperative outcomes in aortic valve surgery within the UK over a 23-year period. METHODS: Data were sourced from the National Institute for Cardiovascular Outcomes Research (NICOR) database. All patients undergoing first-time isolated reoperative aortic valve replacement between 1996 and 2019 in the UK were included. Concomitant procedures, homograft implantation or aortic root enlargement were excluded. Propensity score matching was utilized to compare outcomes and risk factors for in-hospital mortality was evaluated through multivariable logistic regression. Final model selection was conducted using Akaike Information Criterion through bootstrapping. The primary end point was in-hospital mortality, and secondary end points included postoperative morbidities. RESULTS: Out of 2371 patients, 24.9% had mechanical and 75% had bioprosthetic valves implanted during the primary procedure. Propensity matched groups of 324 patients each, were compared. In-hospital mortality for mechanical and bioprosthetic valve explants was 7.1% and 5.9%, respectively (P = 0.632). On multivariable logistic regression analysis, valve type was not a risk factor for mortality [odds ratio (OR) 0.62, 95% confidence interval (CI) 0.37-1.05; P = 0.1]. Age (OR 1.03, 95% CI 1.01-1.05; P < 0.05), left ventricular ejection fraction (OR 1.62, 95% CI 1.08-2.42; P < 0.05), creatinine ≥ 200 mg/dl (OR 2.21, 95% CI 1.17-4.04; P < 0.05) and endocarditis (OR 2.66, 95% CI 1.71-4.14; P < 0.05) emerged as risk factors for mortality. CONCLUSIONS: The type of valve initially implanted (mechanical or bioprosthetic) did not determine mortality. Instead, age, left ventricular ejection fraction, renal impairment and endocarditis were significant risk factors for in-hospital mortality.
No takes yet. Share an insight, caveat, or question.
Narayan et al. (2024) conducted a cohort in First-time isolated reoperative aortic valve replacement (n=2,371). Mechanical valve explant vs. Bioprosthetic valve explant was evaluated on In-hospital mortality (OR 0.62, 95% CI 0.37-1.05, p=0.1). The type of explanted valve (mechanical vs bioprosthetic) did not significantly affect in-hospital mortality during reoperative aortic valve replacement (7.1% vs 5.9%; OR 0.62; 95% CI 0.37-1.05; P=0.1).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: