Answers are grounded in this paper and cite their sources.
Density-gradient centrifugation is a label-free approach that has been extensively used for cell separations. Though elegant, this process is time-consuming (>30 min), subjects cells to high levels of stress (>350 g) and relies on user skill to enable fractionation of cells that layer as a narrow band between the density-gradient medium and platelet-rich plasma. We hypothesized that microfluidic adaptation of this technique could transform this process into a rapid fractionation approach where samples are separated in a continuous fashion while being exposed to lower levels of stress (<100 g) for shorter durations of time (<3 min). To demonstrate proof-of-concept, we designed a microfluidic density-gradient centrifugation device and constructed a setup to introduce samples and medium like Ficoll in a continuous, pump-less fashion where cells and particles can be exposed to centrifugal force and separated via different outlets. Proof-of-concept studies using binary mixtures of low-density polystyrene beads (1.02 g/cm³) and high-density silicon dioxide beads (2.2 g/cm³) with Ficoll-Paque (1.06 g/cm³) show that separation is indeed feasible with >99% separation efficiency suggesting that this approach can be further adapted for separation of cells.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: