Key result
BP telemonitoring more than doubles office BP control rates vs. standard care at 30.5%.
Why the study?
In Mexico, less than half of treated hypertensive patients reach BP targets, and the efficacy of BP telemonitoring to achieve BP control has been poorly studied.
Does blood pressure telemonitoring improve the achievement of blood pressure goals in patients with uncontrolled hypertension compared to standard medical care?
RCT (n=178)
Open-label
randomized
Does blood pressure telemonitoring improve the achievement of blood pressure goals in patients with uncontrolled hypertension compared to standard medical care?
Blood pressure telemonitoring significantly improves the achievement of short-term blood pressure control goals in patients with uncontrolled hypertension compared to standard medical care.
Answers are grounded in this paper and cite their sources.
BPT may enhance short-term BP control in Mexican patients with uncontrolled hypertension; leaves open durability and event reduction in routine practice.
Background: In Mexico less than half of the treated hypertensive patients reach blood pressure (BP) targets. Most hypertensive individuals rely on the standard medical care (SMC) to achieve the BP control goals; however, the efficacy of BP telemonitoring (BPT) to achieve BP targets has been poorly studied. Aim: To compare the efficacy of BPT versus SMC to achieve BP goals in patients with uncontrolled hypertension. Methods: A two-arm, open-label clinical trial was conducted in patients ≥18 years with uncontrolled hypertension. The participants were randomized to 2 arms (BPT vs SMC) and followed for 12 weeks. For the statistical analysis, the chi-squared test and covariance were used. Results: One hundred and seventy-eight participants were included, BPT (n = 94) and SMC (n = 84), after 12 weeks of follow up, we observed a baseline-adjusted reduction in systolic BP with both BPT (-13.5 [1.3] mmHg) and the SMC (-5.9 [1.4] mmHg; p < 0.001) but a greater decrease with BPT (p < 0.001). Likewise, we found a baseline-adjusted reduction of diastolic BP with BPT (-6.9 [0.9] mmHg) and SMC (-2.7 [0.9] mmHg) (p = 0.007) with a more significant percentage change from baseline with BPT (-6.8% [1.0] vs 2.5% [1.1]; p = 0.007). In the BPT arm, a larger proportion of patients achieved the BP target versus SMC (30.5% vs 12.8%; p = 0.005). Conclusion: BPT showed a greater proportion of patients achieving office BP control goals (<140/90 mmHg), compared to standard medical care.
No takes yet. Share an insight, caveat, or question.
Ramos-Zavala et al. (2023) conducted an RCT in uncontrolled hypertension (n=178). Blood pressure telemonitoring vs. Standard medical care was evaluated on Achievement of office BP control goals (<140/90 mmHg) (p=0.005). Blood pressure telemonitoring resulted in a greater proportion of patients achieving office BP control goals compared to standard medical care (30.5% vs 12.8%; p=0.005).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: