Key result
Cocoon septal occluder achieves ~99% permanent implantation success for secundum ASD closure.
Why the study?
Large follow-up studies evaluating the procedural and long-term outcomes of the Cocoon septal occluder for secundum ASD closure were missing.
Does the Cocoon septal occluder provide safe and effective closure in patients with secundum atrial septal defects?
Cohort (n=4,008)
Yes
Does the Cocoon septal occluder provide safe and effective closure in patients with secundum atrial septal defects?
The Cocoon septal occluder demonstrates high procedural success and excellent long-term safety for the closure of secundum atrial septal defects in a large, international cohort.
Answers are grounded in this paper and cite their sources.
May support Cocoon occluder for secundum ASD in selected patients; leaves open randomized comparisons to approved devices.
BACKGROUND: The Cocoon septal occluder (CSO) is a new generation double disk occluder device for catheter closure of the secundum atrial septal defect (ASD). Initial clinical evaluations with the use of this device have shown quite satisfactory results but large follow-up studies are missing. In this international multicenter study, we present procedural and follow-up data from 4008 patients with secundum ASD who underwent catheter closure with the use of CSO. METHODS: The study cohort consisted of 1853 pediatric and 2155 adult patients with secundum ASD treated with the CSO. Patients were enrolled retrospectively from 11 international centers and were followed for a mean period of 43 months (range 12-84 months), postprocedural. Clinical, electrocardiographic, echocardiographic, procedural, and follow-up data were collected from each collaborating hospital. RESULTS: The CSO was permanently implanted in 3983 patients (99.4%). Echocardiographic evaluation at one month follow-up revealed complete closure in 99.6% of those patients who had a device implanted. Thrombus formation in one adult patient was the only major device related to procedural complication. During the follow-up period, no patient developed cardiac erosions, allergic reactions to nickel, or other major complications. CONCLUSIONS: Implantation of CSO provided satisfactory procedural and follow-up results with high success and no device-related cardiac erosions and nickel allergy.
No takes yet. Share an insight, caveat, or question.
Thanopoulos et al. (2021) conducted a cohort in secundum atrial septal defect (ASD) (n=4,008). Cocoon septal occluder (CSO) was evaluated on Permanent implantation success. Catheter closure of secundum atrial septal defects using the Cocoon septal occluder achieved permanent implantation in 99.4% of patients and complete closure in 99.6% at one month.
Synapse has enriched 10 related papers. Consider them for comparative context: